Лого Српског лекарског друштва

Часопис Српског лекарског друштва

Српски архив за целокупно лекарство

Serbian Archives of Medicine

еКорпус – библиографски запис

Компаративна анализа једностране и конвенционалне скелетиране протезе применом методе коначних елемената

Comparative Analysis of Unilateral Removable Partial Denture and Classical Removable Partial Denture by Using Finite Element Method

Katarina Radović; Aleksandra Čairović; Aleksandar Todorović; Ivica Stančić; Aleksandar Grbović

Часопис
Serbian Archives of Medicine
Објављено
Srp Arh Celok Lek. 2010;138(11–12):706–713.
Врста рада
ORIGINAL ARTICLES

Abstract

Introduction Various mobile devices are used in the therapy of unilateral free-end saddle. Unilateral dentures with precise connectivity elements are not used frequently. In this paper the problem of applying and functionality of unilateral free-end saddle denture without major connector was taken into consideration.

Objective The aim was to analyze and compare a unilateral RPD (removable partial denture) and a classical RPD by calculating and analyzing stresses under different loads.

Methods 3D models of unilateral removable partial denture and classical removable partial denture with casted clasps were made by using computer program CATIA V5 (abutment teeth, canine and first premolar, with crowns and abutment tissues were also made). The models were built in full-scale. Stress analyses for both models were performed by applying a force of 300 N on the second premolar, a force of 500 N on the first molar and a force of 700 N on the second molar.

Results The Fault Model Extractor (FME) analysis and calculation showed the complete behaviour of unilateral removable partial denture and abutments (canine and first premolar), as well as the behaviour of RPD under identical loading conditions. Applied forces with extreme values caused high stress levels on both models and their abutments within physiological limits.

Conclusion Having analyzed stresses under same conditions, we concluded that the unilateral RPD and classical RPD have similar physiological values

Keywords: unilateral free-end denture; finite element method; stress distribution