Лого Српског лекарског друштва

Часопис Српског лекарског друштва

Српски архив за целокупно лекарство

Serbian Archives of Medicine

еКорпус – библиографски запис

Abnormalities in the thickness of the retinal ganglion cell / inner plexiform layer in age-related macular degeneration

ПРОМЕНЕ ДЕБЉИНЕ СЛОЈА ГАНГЛИЈСКИХ ЋЕЛИЈА И УНУТРАШЊЕГ ПЛЕКСИФОРМНОГ СЛОЈА КОД БОЛЕСНИКА СА СЕНИЛНОМ ДЕГЕНЕРАЦИЈОМ ЖУТЕ МРЉЕ

Maja Živković; Vesna Jakšić; Marko Zlatanović; Sanja Sefić-Kasumović; Aleksandra Radosavljević; Nevena Zlatanović; Gordana Zlatanović; Jasmina Đorđević-Jocić; Predrag Jovanović; Marija Radenković; Svetlana Jovanović

Часопис
Serbian Archives of Medicine
Објављено
Srp Arh Celok Lek. 2020;148(11–12):727–731.
Врста рада
ORIGINAL ARTICLES

Abstract

Introduction/Objective The study aims to analyze the thickness of both the ganglion cell layer and the inner plexiform layer (GCL + IPL) among patients suffering from dry and wet form of age-related macular degeneration (AMD).

Methods One hundred ninety-five patients with AMD participated in the study, along with 94 healthy individuals (mean age 75.2 ± 7.8 years; range 55–86). They were divided into three groups: the first group, or group I, included 100 patients suffering from wet AMD; the second group, or group II, included 95 patients afflicted with dry AMD; the final 94 patients made up the control group, group III, of healthy individuals without systemic or ocular diseases. Measurements such as the average macular thickness, the average and minimum GCL + IPL thickness, and the GCL + IPL thickness in all six sectors were obtained by Cirrus spectral-domain optical coherence tomography (SD-OCT, Carl Zeiss Meditec, Inc., Dublin, CA, USA). SPSS version 20.0 was used to analyze the data, while the level of statistical significance was set at p < 0.05.

Results In the case of patients with wet AMD, the average value for GCL + IPL thickness was 43.13 μm, for patients with dry AMD the value was 66.73 μm, and the average thickness measured for the control group was 86.23 μm. There was a statistically significant difference between the average GCL + IPL and minimum GCL + IPL thicknesses between the groups (p < 0.001). Lower values were noted for patients with wet AMD (p < 0.001) than those with dry AMD. In the latter, the average GCL + IPL and the minimum GCL + IPL thicknesses were lower than those of the healthy participants, at a level of statistical significance (p < 0.001).

Conclusion Participants with AMD exhibited thinner GCL + IPL than the healthy participants, as did the participants with wet AMD when compared to the participants with dry AMD.

Keywords: dry AMD; wet AMD; ganglion cell layer; ganglion cell complex